Logo
 


RESOURCES

Collapse all | Expand all
Approximate Floor Area in Square Feet from One Cubic Yard of Concrete for a Given Slab Thickness
Slab Thickness (inches)
Floor Area (sq. ft.)
Slab Thickness (inches)
Floor Area (sq. ft.)
Slab Thickness (inches)
Floor Area (sq. ft.)
1
324
5
65
9
36
1-1/4
259
5-1/4
62
9-1/4
35
1-1/2
216
5-1/2
59
9-1/2
34
2
162
5-3/4
56
9-3/4
33
2-1/4
144
6
54
10
32
2-1/2
130
6-1/4
52
10-1/4
31
2-3/4
118
6-1/2
50
10-1/2
31
3
108
6-3/4
48
10-3/4
30
3-1/4
100
7
46
11
29-1/2
3-1/2
93
7-1/4
44
11-1/4
29
3-3/4
86
7-1/2
43
11-1/2
28
4
81
7-3/4
42
11-3/4
27-1/2
4-1/4
76
8
40
12
27
4-1/2
72
8-1/4
39
12-1/4
26-1/2
4-3/4
68
8-1/2
38
12-1/2
26
8-3/4
37
12-3/4
25-1/2
For other floor thickness, use:
Floor area (ft2) = 324 ÷ Slab thickness (in.)

(Metric)
Floor area in square meters from 1 cubic meter of concrete for a given slab thickness
Floor area (m2) = 1000 ÷ Slab thickness (mm)
Aggregate Extension
Using silica sand
Number of pounds ÷ 165.36 = Additional cu. ft.
Coverage for Coatings
Thickness of Coating Applied (1000 mils = 1 in.)
Coverage Per U.S. Gallon 100% Solids System
1/4 in.
=
250 mils
6.4 ft2
3/16 in.
=
187.5 mils
8.5 ft2
1/8 in.
=
125 mils
12.8 ft2
 
=
100 mils
16.0 ft2
1/16 in.
=
62.5 mils
25.5 ft2
 
=
50 mils
32.0 ft2
1/32 in.
=
31.25 mils
51.0 ft2
 
=
20 mils
80.0 ft2
1/64 in.
=
15.625 mils
102.0 ft2
 
=
10 mils
160.0 ft2
 
=
5 mils
320.0 ft2
 
=
1 mils
1,600 ft2
Coverage - Wet and Dry Film Thickness, mils (mm)
Sq. Ft. per gallon per coat Avg. Dry Film Avg. Wet Film
50 14 - 15 (0.35 - 0.38) 32 - 33 (0.81 - 0.83)
60 12 - 13 (0.30 - 0.33) 26 - 27 (0.66 - 0.68)
80 9 - 10 (0.23 - 0.25) 20 - 21 (0.51 - 0.53)
100 7 - 8 (0.18 - 0.20) 16 - 17 (0.41 - 0.43)
Note: Coverage rates are theoretical on smooth-surfaced, properly primed substances.
Important: Warranty applications require a minimum 12 dry mils film thickness.
Sealant Coverage Chart
Coverage for 1 Gallon Pail (3.78 L)
Depth Width
1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1"
1/8" 1230 620 410 310 246 205 176 154
1/4"   310 248 154 123 102 88 74
3/8"     136 102 82 68 58 49
1/2"       74 61 51 44 37
Linear Feet Per One Gallon Pail

Coverage for 10.1 FL. OZ. Cartridge (298 mL)
Depth Width
1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1"
1/8" 97 49 32 24 19 16 13 12
1/4"   24 19 12 9 7 6 5
3/8"     10 7 6 5 4.5 4
1/2"       5.5 5 4 3.5 3
Linear Feet Per 10.1 FL. OZ. Cartridge

Coverage Chart for 5 Gallon Pail (18.9 L)
Depth Width
1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1"
1/8" 6150 3100 2050 1540 1230 1025 870 770
1/4"   1540 1240 770 615 510 440 370
3/8"     680 510 410 310 290 245
1/2"       370 305 245 220 185
Linear Feet Per 5 Gallon Pail

Coverage for 28 FL. OZ. Cartridge (828 mL)
Depth Width
1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1"
1/8" 268 137 88 66 53 44 36 33
1/4"   66 53 33 25 19 17 14
3/8"     27 19 17 14 12 11
1/2"       15 14 11 10 8
Linear Feet Per 28 FL. OZ. Cartridge

Coverage Chart for 52 Gallon Drum (196.8 L)
Depth Width
1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1"
1/8"   63960 32240 16016 12792 10660 9048 8008
1/4"     12896 8008 6396 5304 4523 3848
3/8"     7072 5304 4264 3224 2907 2548
1/2"       3848 3172 2548 2261 1294
Linear Feet Per 52 Gallon Drum

Coverage for 20 FL. OZ. Sausage (591 mL)
Depth Width
1/8" 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1"
1/8" 192 97 63 48 39 31 27 24
1/4"   48 39 24 19 15 14 12
3/8"     21 15 11 10 9 7
1/2"       11 10 8 7 5
Linear Feet Per 20 FL. OZ. Sausage

Primer Coverage Recommendations
     For One(1) quart of primer, coverage is as follows:     
1 unit
5 units
7 gallons
103 cartridges
35 cartridges
5 gallons pail
1.5 gallon unit
1 gallon unit
10.1 fl.oz. cartridge
28 fl.oz. cartridge
Note: All values are approximations and can vary
due to joint dimension variations, porosity, and
texture of substrates.
Mortar Components
Mortar Component Densities
Mortar Component Bulk Density (lbs/ft3)
Portland Cement 94
Blended Cement Obtain From Manufacturer
Hydraulic Cement Obtain From Manufacturer
Hydrated Lime 40
Lime Putty 80
Masons Sand 80


Mortar Type Proportions by volume (cementitious materials)
Portland Cement Hydrated Lime
M 1 ¼
S 1 Over ¼ to ½
N 1 Over ½ to 1 ¼
O 1 Over 1 ¼ to 2 ½
ASTM C 270 Property Specifications
Mortar Type Average Compressive Strength at 28 Days (psi) Water Retention (%) Air Content max. % Aggregate Ratio
M 2,500 75 12 Not less than 2¼ and not more than 3½ times the sum of the separate volumes of cementitious materials
S 1,500 75 12
N 750 75 14B
O 350 75 14B

Mixing Order:
1. Water  75% of Total 5. Portland Cement All
2. Sand       Half   6. Sand    Balance
3. Lime           All  7. Water To Workable Consistency
4. Mix  2 Minutes 8. Mix 5 Full Minutes

Shovels of Sand:
If a cubic foot box is not available, simply take a 5 gallon bucket and count how many shovels it takes to fill up 1 ½ buckets, this will equal one cubic foot.

Perlite Coverage Chart
Approximate Coverage(a)
Sq. ft. of wall area(b) 1"Cavity 2"Cavity 3"Cavity 6"Block 8"Block 12"Block
100 2 4 6 5 7 12
500 10 21 31 23 33 58
1,000 21 42 62 46 65 118
2,000 42 84 124 96 130 236
3,000 63 126 186 138 195 354
5,000 105 210 310 230 325 590
7,000 147 294 434 322 455 826
10,000 210 420 620 460 650 1,180
(a) 4-cubic foot bags required to fill
(b) a standard 8"x16" block equals 0.89 sq.ft. Multiply the number of blocks times 0.89 to calculate the total square footage needed.
Viscosity Guidelines
Viscosity in
=
Similar to
Centpoise
=
Consitency to
1
=
Water
500
=
# 10 Motor Oil
2,500
=
Pancake Syrup
10,000
=
Honey
25,000
=
Chocolate Syrup
50,000
=
Catsup
25,000
=
Peanut Butter
1,000,000
=
Paste-Caulking Material
Wind Chill Chart
Wind Chill Chart